{"product_id":"zeiss-iolmaster-500-reacondicionado-biometro-optico-para-catarata","title":"ZEISS IOLMaster 500 reacondicionado | Biómetro óptico para Cálculo de lente Intraocular","description":"\u003carticle style=\"font-family:'Helvetica Neue',Helvetica,Arial,sans-serif;color:#334155;line-height:1.75;max-width:1100px;margin:0 auto;\"\u003e\n\n\u003c!-- ENCABEZADO --\u003e\n\n\u003cheader style=\"background:linear-gradient(135deg,#102c4c 0%,#19619a 100%);padding:45px 25px;border-radius:16px;text-align:center;margin-bottom:35px;color:#ffffff;\"\u003e\n\n\u003cp style=\"font-size:13px;letter-spacing:2px;font-weight:700;color:#bfdbfe;margin-bottom:12px;\"\u003e\nTECNOLOGÍA OFTALMOLÓGICA PROFESIONAL\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:32px;line-height:1.25;margin:0 0 15px;color:#ffffff;\"\u003e\nZEISS IOLMaster 500\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size:19px;color:#e0f2fe;margin:0 0 24px;\"\u003e\nBiometría óptica de precisión para cirugía de catarata y cálculo de lentes intraoculares\n\u003c\/p\u003e\n\n\u003cdiv style=\"display:inline-block;background:#16a34a;color:#ffffff;padding:9px 18px;border-radius:30px;font-size:14px;font-weight:700;margin:5px;\"\u003e\nEQUIPO REACONDICIONADO\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:inline-block;background:#ffffff;color:#14532d;padding:9px 18px;border-radius:30px;font-size:14px;font-weight:700;margin:5px;\"\u003e\n12 MESES DE GARANTÍA EN MÉXICO\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:15px;color:#dbeafe;margin:25px auto 0;max-width:780px;\"\u003e\nBiometría ocular sin contacto mediante interferometría de coherencia parcial, queratometría telecéntrica y herramientas de cálculo de potencia de lente intraocular en una sola plataforma.\n\u003c\/p\u003e\n\n\u003c\/header\u003e\n\n\u003c!-- DESCRIPCIÓN GENERAL --\u003e\n\n\u003csection style=\"padding:10px 15px;margin-bottom:35px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;border-bottom:2px solid #dbeafe;padding-bottom:12px;\"\u003e\nBiometría óptica para planificación de cirugía de catarata\n\u003c\/h2\u003e\n\n\u003cp\u003e\nEl \u003cstrong\u003eZEISS IOLMaster 500\u003c\/strong\u003e es un biómetro óptico diseñado para obtener mediciones oculares fundamentales en la evaluación preoperatoria y el cálculo de la potencia de lentes intraoculares (LIO).\n\u003c\/p\u003e\n\n\u003cp\u003e\nUtiliza tecnología de \u003cstrong\u003einterferometría de coherencia parcial (PCI)\u003c\/strong\u003e para medir la longitud axial del ojo sin contacto, reduciendo la necesidad de procedimientos de biometría por ultrasonido en los pacientes que pueden medirse mediante esta tecnología.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIntegra mediciones de longitud axial, curvatura corneal anterior, profundidad de cámara anterior y diámetro corneal horizontal blanco a blanco (WTW).\n\u003c\/p\u003e\n\n\u003cp\u003e\nSu sistema de \u003cstrong\u003equeratometría telecéntrica\u003c\/strong\u003e permite obtener mediciones de curvatura corneal con menor dependencia de la distancia de trabajo, favoreciendo la consistencia de los resultados.\n\u003c\/p\u003e\n\n\u003cp\u003e\nEl IOLMaster 500 es una solución para clínicas oftalmológicas, hospitales, centros de cirugía de catarata y consultorios especializados que buscan una plataforma de biometría óptica reconocida.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- PRINCIPALES CAPACIDADES --\u003e\n\n\u003csection style=\"margin-bottom:40px;padding:0 15px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;margin-bottom:22px;\"\u003e\nPrincipales capacidades diagnósticas\n\u003c\/h2\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:18px;\"\u003e\n\n\u003cdiv style=\"background:#f8fafc;padding:23px;border:1px solid #e2e8f0;border-radius:12px;border-top:4px solid #2563eb;\"\u003e\n\n\u003ch3 style=\"font-size:19px;color:#163b65;margin-top:0;\"\u003e\nLongitud axial\n\u003c\/h3\u003e\n\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e\nMedición óptica de la longitud axial mediante interferometría de coherencia parcial, parámetro fundamental para el cálculo de potencia de lentes intraoculares.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f8fafc;padding:23px;border:1px solid #e2e8f0;border-radius:12px;border-top:4px solid #2563eb;\"\u003e\n\n\u003ch3 style=\"font-size:19px;color:#163b65;margin-top:0;\"\u003e\nQueratometría telecéntrica\n\u003c\/h3\u003e\n\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e\nMedición de la curvatura corneal anterior para determinar valores queratométricos y astigmatismo utilizados en la planificación quirúrgica.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f8fafc;padding:23px;border:1px solid #e2e8f0;border-radius:12px;border-top:4px solid #2563eb;\"\u003e\n\n\u003ch3 style=\"font-size:19px;color:#163b65;margin-top:0;\"\u003e\nProfundidad de cámara anterior\n\u003c\/h3\u003e\n\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e\nMedición de la profundidad de la cámara anterior, utilizada por determinadas fórmulas biométricas para mejorar la estimación de la posición efectiva del lente.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f8fafc;padding:23px;border:1px solid #e2e8f0;border-radius:12px;border-top:4px solid #2563eb;\"\u003e\n\n\u003ch3 style=\"font-size:19px;color:#163b65;margin-top:0;\"\u003e\nDiámetro blanco a blanco\n\u003c\/h3\u003e\n\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e\nMedición del diámetro corneal horizontal visible (WTW), útil como parámetro complementario de evaluación y planificación.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- TECNOLOGÍA --\u003e\n\n\u003csection style=\"background:#eff6ff;padding:30px 25px;border-radius:14px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;margin-top:0;\"\u003e\nTecnología de biometría óptica ZEISS\n\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:19px;color:#1d4ed8;\"\u003e\nInterferometría de coherencia parcial (PCI)\n\u003c\/h3\u003e\n\n\u003cp\u003e\nLa tecnología PCI permite realizar mediciones ópticas de longitud axial sin contacto con la superficie ocular.\n\u003c\/p\u003e\n\n\u003cp\u003e\nAl evitar la compresión corneal asociada con determinadas técnicas de ultrasonido por contacto, la biometría óptica constituye una alternativa para la planificación preoperatoria.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;color:#1d4ed8;\"\u003e\nQueratometría telecéntrica\n\u003c\/h3\u003e\n\n\u003cp\u003e\nEl sistema emplea queratometría telecéntrica para medir la curvatura anterior de la córnea con independencia de pequeñas variaciones en la distancia de medición.\n\u003c\/p\u003e\n\n\u003cp\u003e\nLos valores queratométricos obtenidos se incorporan al cálculo biométrico de lentes intraoculares.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;color:#1d4ed8;\"\u003e\nMedición rápida y sin contacto\n\u003c\/h3\u003e\n\n\u003cp\u003e\nSu flujo de adquisición permite realizar una secuencia de mediciones en ambos ojos sin contacto físico con la córnea.\n\u003c\/p\u003e\n\n\u003cp\u003e\nDe acuerdo con ZEISS, el sistema puede completar la biometría de ambos ojos en menos de 60 segundos bajo condiciones adecuadas de exploración.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size:13px;color:#475569;\"\u003e\nEl tiempo de medición depende de las características oculares, la colaboración del paciente y las condiciones de adquisición.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- CÁLCULO DE LIO --\u003e\n\n\u003csection style=\"padding:0 15px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;border-bottom:2px solid #dbeafe;padding-bottom:12px;\"\u003e\nCálculo de potencia de lentes intraoculares\n\u003c\/h2\u003e\n\n\u003cp\u003e\nEl IOLMaster 500 incorpora herramientas para la selección de potencia de lentes intraoculares mediante diferentes fórmulas biométricas.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;color:#1d4ed8;\"\u003e\nFórmulas de cálculo\n\u003c\/h3\u003e\n\n\u003cul style=\"padding-left:23px;\"\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eHaigis:\u003c\/strong\u003e utiliza parámetros biométricos que incluyen longitud axial y profundidad de cámara anterior.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eHoffer Q:\u003c\/strong\u003e fórmula de cálculo de potencia intraocular utilizada en biometría convencional.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eHolladay 1:\u003c\/strong\u003e fórmula de cálculo de LIO basada en parámetros biométricos y constantes del lente.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eHolladay 2:\u003c\/strong\u003e fórmula que puede incorporar parámetros adicionales para estimar la posición efectiva del lente.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eSRK\/T:\u003c\/strong\u003e fórmula teórica ampliamente utilizada en cirugía de catarata.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:10px;\"\u003e\n\u003cstrong\u003eSRK II:\u003c\/strong\u003e fórmula histórica incluida en la plataforma.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size:19px;color:#1d4ed8;margin-top:25px;\"\u003e\nCálculo después de cirugía refractiva\n\u003c\/h3\u003e\n\n\u003cp\u003e\nLa plataforma contempla herramientas como \u003cstrong\u003eHaigis-L\u003c\/strong\u003e para el cálculo de potencia de lente intraocular en pacientes con antecedentes de cirugía refractiva corneal, incluyendo LASIK, PRK y LASEK para corrección de miopía o hipermetropía.\n\u003c\/p\u003e\n\n\u003cp\u003e\nEstas capacidades son especialmente relevantes para centros quirúrgicos que atienden pacientes con antecedentes de procedimientos refractivos.\n\u003c\/p\u003e\n\n\u003cp style=\"font-size:14px;background:#f1f5f9;padding:15px;border-radius:8px;\"\u003e\n\u003cstrong\u003eImportante:\u003c\/strong\u003e la disponibilidad de cada fórmula, módulo y función depende de la versión de software instalada. Se confirmará individualmente antes de la venta.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- APLICACIONES CLÍNICAS --\u003e\n\n\u003csection style=\"background:#f8fafc;padding:30px 25px;border-radius:14px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;margin-top:0;\"\u003e\nAplicaciones clínicas\n\u003c\/h2\u003e\n\n\u003cul style=\"padding-left:23px;\"\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eCirugía de catarata:\u003c\/strong\u003e obtención de parámetros biométricos preoperatorios y cálculo de potencia de lente intraocular.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eCirugía refractiva del cristalino:\u003c\/strong\u003e apoyo a la selección de potencia de lentes intraoculares.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003ePacientes con cirugía refractiva previa:\u003c\/strong\u003e utilización de herramientas biométricas específicas cuando están disponibles.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eEvaluación de miopía axial:\u003c\/strong\u003e medición de longitud axial como parámetro anatómico ocular.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003ePlanificación quirúrgica:\u003c\/strong\u003e integración de biometría y queratometría para la selección de lentes.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eDocumentación clínica:\u003c\/strong\u003e generación de resultados biométricos para el expediente y seguimiento preoperatorio.\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- FICHA TÉCNICA --\u003e\n\n\u003csection style=\"padding:0 15px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;border-bottom:2px solid #dbeafe;padding-bottom:12px;\"\u003e\nFicha técnica ZEISS IOLMaster 500\n\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;min-width:440px;\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;width:38%;border:1px solid #dbe4ee;\"\u003eFabricante\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eCarl Zeiss Meditec\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eModelo\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eIOLMaster 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eTipo de equipo\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eBiómetro óptico\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eTecnología\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eInterferometría de coherencia parcial (PCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eMétodo de medición\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eÓptico, sin contacto\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eLongitud axial\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e14 a 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eResolución mostrada de longitud axial\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e0.01 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eRadios de curvatura corneal\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e5 a 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eResolución mostrada de radios corneales\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e0.01 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eProfundidad de cámara anterior\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e1.5 a 6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eResolución mostrada de cámara anterior\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e0.01 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eDiámetro blanco a blanco (WTW)\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e8 a 16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eResolución mostrada WTW\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eQueratometría\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eTelecéntrica, superficie corneal anterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eFórmulas de LIO\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eHaigis, Hoffer Q, Holladay 1 y 2, SRK II y SRK\/T\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eCirugía refractiva previa\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eHaigis-L y métodos disponibles según software\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eOptimización de constantes\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eCompatible, según configuración\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eExportación y conectividad\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eSegún versión, licencias e interfaces instaladas\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eCondición\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e\u003cstrong\u003eReacondicionado\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eGarantía\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003e\n\u003cstrong\u003e12 meses en México\u003c\/strong\u003e, conforme a condiciones escritas\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eSoftware y accesorios\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eSe verifican individualmente antes de cotizar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003eDisponibilidad\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eSujeta a confirmación\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#eff6ff;\"\u003e\n\u003cth style=\"padding:14px;text-align:left;border:1px solid #dbe4ee;\"\u003ePrecio y entrega\u003c\/th\u003e\n\u003ctd style=\"padding:14px;border:1px solid #dbe4ee;\"\u003eCotización en MXN con impuestos y logística aplicables\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:13px;color:#64748b;margin-top:12px;\"\u003e\nLos rangos de medición corresponden a las especificaciones del modelo publicadas por ZEISS. La resolución indicada representa el incremento mostrado en pantalla.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- VENTAJAS --\u003e\n\n\u003csection style=\"background:#f0fdf4;border:1px solid #bbf7d0;padding:30px 25px;border-radius:14px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:24px;color:#166534;margin-top:0;\"\u003e\nVentajas de adquirir un ZEISS IOLMaster 500 reacondicionado\n\u003c\/h2\u003e\n\n\u003cul style=\"padding-left:23px;\"\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eTecnología ZEISS:\u003c\/strong\u003e plataforma reconocida de biometría óptica para cirugía de catarata.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eBiometría sin contacto:\u003c\/strong\u003e mediciones que no requieren contacto directo con la superficie ocular.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eEvaluación integral:\u003c\/strong\u003e longitud axial, queratometría, profundidad de cámara anterior y diámetro blanco a blanco.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003ePlanificación quirúrgica:\u003c\/strong\u003e herramientas para el cálculo de potencia de lentes intraoculares mediante diferentes fórmulas.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eInversión optimizada:\u003c\/strong\u003e acceso a tecnología especializada con un costo potencialmente inferior al de un equipo nuevo.\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eGarantía de 12 meses en México:\u003c\/strong\u003e respaldo conforme a las condiciones comerciales escritas.\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- CONDICIONES COMERCIALES --\u003e\n\n\u003csection style=\"padding:0 15px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:25px;color:#163b65;border-bottom:2px solid #dbeafe;padding-bottom:12px;\"\u003e\n¿Qué incluye nuestra cotización?\n\u003c\/h2\u003e\n\n\u003cp\u003e\nLa propuesta comercial se prepara considerando las características de la unidad disponible.\n\u003c\/p\u003e\n\n\u003cul style=\"padding-left:23px;\"\u003e\n\n\u003cli\u003ePrecio final expresado en pesos mexicanos.\u003c\/li\u003e\n\n\u003cli\u003eImpuestos aplicables.\u003c\/li\u003e\n\n\u003cli\u003eVersión de software instalada.\u003c\/li\u003e\n\n\u003cli\u003eFórmulas biométricas y funciones habilitadas.\u003c\/li\u003e\n\n\u003cli\u003eRelación de accesorios incluidos.\u003c\/li\u003e\n\n\u003cli\u003eCondiciones de garantía de 12 meses.\u003c\/li\u003e\n\n\u003cli\u003eFotografías reales de la unidad disponible.\u003c\/li\u003e\n\n\u003cli\u003eDisponibilidad y plazo estimado de entrega.\u003c\/li\u003e\n\n\u003cli\u003eImportación, transporte y logística correspondientes.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:14px;background:#f8fafc;padding:16px;border-radius:8px;color:#475569;\"\u003e\n\u003cstrong\u003eImportante:\u003c\/strong\u003e las fotografías de catálogo son ilustrativas. Antes de concretar la operación se proporcionarán imágenes de la unidad disponible y los detalles de su configuración. La disponibilidad está sujeta a confirmación.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- PREGUNTAS FRECUENTES --\u003e\n\n\u003csection style=\"background:#f8fafc;padding:30px 25px;border-radius:14px;margin-bottom:40px;\"\u003e\n\n\u003ch2 style=\"font-size:24px;color:#163b65;margin-top:0;\"\u003e\nPreguntas frecuentes\n\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿El IOLMaster 500 realiza biometría sin contacto?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nSí. Utiliza interferometría de coherencia parcial para la medición óptica de longitud axial sin contacto con la córnea.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿Incluye queratometría?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nSí. Incorpora queratometría telecéntrica para medir la curvatura de la superficie corneal anterior.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿Permite calcular lentes intraoculares?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nSí. La plataforma dispone de fórmulas biométricas para el cálculo de potencia de lentes intraoculares. Su disponibilidad específica se confirmará según el software instalado.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿Puede utilizarse en pacientes con cirugía refractiva previa?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nEl IOLMaster 500 contempla herramientas como Haigis-L para casos posteriores a cirugía refractiva corneal. La función correspondiente debe verificarse en la unidad cotizada.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿Sustituye siempre a la biometría ultrasónica?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nNo necesariamente. En pacientes con opacidades densas de medios u otras condiciones que impidan obtener una medición óptica confiable, puede requerirse biometría ultrasónica complementaria.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;color:#1e40af;\"\u003e\n¿Cuánto tiempo tiene de garantía?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nEl equipo reacondicionado cuenta con garantía de 12 meses en México, conforme a las condiciones escritas de venta.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- CONTACTO --\u003e\n\n\u003csection style=\"background:linear-gradient(135deg,#102c4c 0%,#1c5683 100%);padding:45px 25px;border-radius:18px;text-align:center;color:#ffffff;\"\u003e\n\n\u003cp style=\"font-size:13px;letter-spacing:1.5px;color:#bfdbfe;font-weight:bold;margin-bottom:10px;\"\u003e\nCOTIZACIONES PARA MÉDICOS, CLÍNICAS Y HOSPITALES\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:28px;line-height:1.3;color:#ffffff;margin-top:0;\"\u003e\nIncorpore biometría óptica ZEISS a su centro oftalmológico\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size:17px;color:#dbeafe;max-width:650px;margin:15px auto 25px;\"\u003e\nSolicite información sobre disponibilidad, precio final, configuración y tiempo estimado de entrega del ZEISS IOLMaster 500 reacondicionado.\n\u003c\/p\u003e\n\n\u003ca href=\"https:\/\/wa.me\/525520891238?text=Hola%2C%20quiero%20cotizar%20el%20ZEISS%20IOLMaster%20500%20reacondicionado.%20Deseo%20conocer%20precio%2C%20configuraci%C3%B3n%20y%20tiempo%20de%20entrega.\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-block;background:#25d366;color:#ffffff;padding:18px 30px;border-radius:9px;text-decoration:none;font-size:17px;font-weight:bold;box-shadow:0 5px 15px rgba(0,0,0,0.18);\"\u003e\n\nSOLICITAR COTIZACIÓN POR WHATSAPP\n\n\u003c\/a\u003e\n\n\u003cp style=\"font-size:14px;color:#cbd5e1;margin-top:25px;\"\u003e\nAtención comercial en Ciudad de México.\n\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- PIE LEGAL --\u003e\n\n\u003cfooter style=\"text-align:right;padding:18px 5px;\"\u003e\n\n\u003cp style=\"font-size:11px;color:#94a3b8;margin:0;\"\u003e\nGRUPO VISION DIGNA S.A.P.I. DE C.V.\n\u003c\/p\u003e\n\n\u003c\/footer\u003e\n\n\u003c\/article\u003e","brand":"Visión Digna","offers":[{"title":"Default Title","offer_id":45275339685939,"sku":null,"price":429000.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0066\/5924\/4096\/files\/Zeiss-IOL500-Background-Removed.webp?v=1793844959","url":"https:\/\/visiondigna.com\/products\/zeiss-iolmaster-500-reacondicionado-biometro-optico-para-catarata","provider":"Visión Digna","version":"1.0","type":"link"}